Proof Load Test According to the Standard NF en 898-2 for an ESL M16 X 200 in Classe 8 with a Zinc Lanthane® Protection 175 + Filmogene

  • The value of the proof Load test is 138 200 N
  • The speed test is 3 mm/minute
  • The value of the proof Load is maintained for 15 seconds before releasing the effort
  • Proof load test according to the standard NF EN 898-2 for an ESL M16 X 200 in classe 8 with a zinc LANTHANE® protection 175 + filmogene
  • Unscrewing the nut
  • No defects found
  • Conformity of Nut