Proof Load Test According to the Standard NF en 898-2 for an ESL M16 X 200 in Classe 8 with a Zinc Lanthane® Protection 175 + Filmogene
- The value of the proof Load test is 138 200 N
- The speed test is 3 mm/minute
- The value of the proof Load is maintained for 15 seconds before releasing the effort
- Proof load test according to the standard NF EN 898-2 for an ESL M16 X 200 in classe 8 with a zinc LANTHANE® protection 175 + filmogene
- Unscrewing the nut
- No defects found
- Conformity of Nut