Low Voltage Limiters for Railway Vehicles in DC Systems

Low Voltage Limiters for Railway Vehicles in DC Systems
Address: ACER VOLTAGE s.r.o.
Bratří Štefanů 1170
500 03 HRADEC KRÁLOVÉ
CZECH REPUBLIC
Phone: +420 491 618 571 Connect: Website: View website Contact: Contact supplier View: View supplier Download: Download

ACER VOLTAGE

Protection of Non-live Parts of Metal Structures in DC Traction Power Supply Systems

  • P60G, P120G – Insulation resistance > 2 GΩ (outdoor and indoor use)
  • P60GI, P120GI – Insulation resistance > 2 GΩ (indoor use)
  • P250G, P400G – Insulation resistance > 1 GΩ (outdoor and indoor use)
  • P250GI, P400GI – Insulation resistance > 1 GΩ (indoor use)

New types of low voltage limiters Type 1 VLD-F based on requirements of EN 50122-1: 2011, which are designed to protect the non-live parts of metallic structures in DC ev. AC traction power supply systems. They are used to effectively protect persons who may come into contact with these parts during lightning strikes or a defect of the tractive overhead line. The limiter has a high internal resistance when voltage on it is less than the nominal level its spark over voltage UVDC and becomes conductive when this level is exceeded. In case of failure arising from a contact between live parts of the power system and traction conductive portion unintentionally associated with return path limiter protects illegal contact voltage that becomes conductive and causes the power is turned off. According to EN 50122-1: 2011, this type of limiter is recommended primarily for connection between the protected area and return circuit in overhead line areas (or pantograph areas) that may be in contact with live conductors or damaged current collector, then the support structures pylons which can become live due to a fault isolation. After re-applied voltage drops below of its nominal level spark over voltage UVDC the limiter returns to the non-conducting state again.

  • P600G – Insulation resistance > 1 GΩ (outdoor and indoor use)
  • P600GI – Insulation resistance > 1 GΩ (indoor use

Power gas discharge tube (GDT) designed for potential equalisation on the installation components of buildings or technological units, which are not electrically connected to each other (according to EN 62305: 2011). It is recommended primarily for bridging of insulated flanges and insulated threaded joints in the pipeline cathodic protected parts of industrial technology.

www.acervoltage.com

Other ACER VOLTAGE Documents

Latest ACER VOLTAGE News

New Low Voltage Limiters for Railway Applications

New Low Voltage Limiters for Railway Applications

The new low voltage limiters are used in DC traction systems, protecting from electric shock when touching non-live metal parts.

Contact ACER VOLTAGE

Use the form opposite to get in touch with ACER VOLTAGE directly to discuss any requirements you might have.








    We'd love to send you the latest news and information from the world of Railway-News. Please tick the box if you agree to receive them.

    For your peace of mind here is a link to our Privacy Policy.

    By submitting this form, you consent to allow Railway-News to store and process this information.

    Subscribe
    Follow Railway-News on LinkedIn
    Follow Railway-News on Twitter